> -----Original Message-----
> From: IBM Mainframe Discussion List 
> [mailto:[EMAIL PROTECTED] On Behalf Of Clark, Kevin D, 
> HRC-Alexandria/EDS
> Sent: Wednesday, April 26, 2006 11:14 AM
> To: [email protected]
> Subject: Re: Master Catalog maxed out w/19k Alias.
> 
> 
> John, 
> 
> Excellent Question:  
> 
> The master catalog holds aliases in two records 1) for the 
> absolute aliases
> and 2) for the Relate to the UserCat.  
> 
> 
> I am researching on which one filled up. So simply adding 
> more UCATS would
> take care if the second issue. 
> 
> But what about the first alias entry record.
> 
> Kevin 

I've never heard of any maximum related to the absolute number of
aliases in a catalog (other than the size of the catalog). I've only
heard about the maximum per usercatalog, based on the CI size of the
master catalog.

--