> -----Original Message----- > From: IBM Mainframe Discussion List > [mailto:[EMAIL PROTECTED] On Behalf Of Clark, Kevin D, > HRC-Alexandria/EDS > Sent: Wednesday, April 26, 2006 11:14 AM > To: [email protected] > Subject: Re: Master Catalog maxed out w/19k Alias. > > > John, > > Excellent Question: > > The master catalog holds aliases in two records 1) for the > absolute aliases > and 2) for the Relate to the UserCat. > > > I am researching on which one filled up. So simply adding > more UCATS would > take care if the second issue. > > But what about the first alias entry record. > > Kevin
I've never heard of any maximum related to the absolute number of aliases in a catalog (other than the size of the catalog). I've only heard about the maximum per usercatalog, based on the CI size of the master catalog. -- John McKown Senior Systems Programmer HealthMarkets Keeping the Promise of Affordable Coverage Administrative Services Group Information Technology This message (including any attachments) contains confidential information intended for a specific individual and purpose, and its content is protected by law. If you are not the intended recipient, you should delete this message and are hereby notified that any disclosure, copying, or distribution of this transmission, or taking any action based on it, is strictly prohibited. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html