I was able to eliminate the IEF170I on STCs by setting the MCSFLAG field in 
IEEACTRT to the following:

MCSFLAG  DC    B'1000000000000000'        
*                0123456789ABCDEF

The WTO now goes to our consoles and to hardcopy since our hardcopy is defined 
as ROUTCODE(ALL) in our CONSOLXX member.  Thanks for the help. 

Quoting David Andrews <[EMAIL PROTECTED]>:

> On Mon, 2006-05-01 at 08:35 -0500, George Dranes wrote:
> > This output is only written to Hardcopy, not the consoles.  In our exit we
> > let the ROUTE codes and MCSFLAGS default.
> 
> We use ROUTCDE=(13),DESC=(6) and then configure SYS1.PARMLIB(CONSOLxx)
> appropriately to route the messages where we want.
> 
> (We don't use ROUTCDE=11 because this results in duplicate IEF196I
> messages when IEFACTRT runs under a WLM initiator.)
> 
> -- 
> David Andrews
> A. Duda and Sons, Inc.
> [EMAIL PROTECTED]
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO