> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Laine, Rogers
> 
> We are currently migrating from a 2066-A02 to a 2086-A04 an 
> having a issue with the HMC TOD & the z/os 1.4 being different times.
>  
> The 2066 CLOCK00 has the TIMEZONE set to W.00.00.00 and the 
> HMC time set to local time with nothing for UTC, but the 
> direction has EAST selected.
>  
> On the 2086 the HMC is set to the local time with TimeZone as 
> America/Chicago and the CLOCK00 has the same W.00.00.00 
> setting, but the z/os time is five hours ahead of time.
>  
> I know the TIMEZONE can be changed to reflect the five hour 
> difference and the suggested method is to use GMT, but has 
> something changed between these two machines?

Just a SSWAG (Semi-Scientific):  When your new machine was installed and
first powered-up, the hardware clock was set to (or remained set to) UTC
aka GMT.  Opportunity appears to exist to "convert" to using GMT plus
timezone offset.

    -jc-

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html