A question just came up from my Information Security dept. about setting
and synching the Mainframe clocks.
We generally reset them whenever we have a full system shutdown and
don't worry about it otherwise but they now want a procedure to
regularly correct clock drift. 

Please correct me if I'm wrong

Hardware Clock - Set via HMC/SE to (In my case) GMT/UTC.

TOD Clock - Set from Hardware clock at LPAR Activation time, not synched
to hardware clock after then.

SIMETR - Set from TOD clock by first LPAR referencing it.  All other
LPARs with same SIMETR will have same time reference. 

The only way to 'correct' GMT/UTC clock drift in a plex using SIMETR
would be to Deactivate all LPARs (using the same reference) then
Activate to get new TOD/Hardware reference.

If using an ETR (9037) TOD clocks are continuously (FSVO continuous)
synched to the ETR and a change to the ETR GMT/UTC setting will be
propagated to all referencing LPARs without need for Deactivation/IPL. 

Thanks all.

Ken Porowski
AVP Systems Software