Hello Victor,

I assume you will be doing a box replacement to install the new box.

Try as hard as possible to define the Partitions, Chpids etc on the new box 
the same as the old box.

That way all cross-box links will be the same.

No need to modify other boxes...

But an IODF activate to keep your site-wide IODF consistent across boxes is 
recommended.

I have done this many times over the last 9 years, it is BAU for me. Never 
had to disturb the other boxes...the applications (across sysplex) just 
kept running while we brought in the new box.

Regards
Bruce Hewson

----------------------------------------------------------------------