 CONSOLE DEVNUM(D907) UNIT(3277-2)        /* MCONS -- ICC D907 */   <<< 
set unit from 3270-X to 3277-2
         NAME(DEVOSC04) AUTH(MASTER) USE(FC) ROUTCODE(ALL) 
         ALTGRP(DEVOSALT) CON(N) DEL(RD) 
         RNUM(13) SEG(14) AREA(NONE) RTME(1/4) MFORM(J,T) 
         PFKTAB(PFKTAB00) 
         MONITOR(JOBNAMES-T,SESS-T) LEVEL(ALL) RBUF(20)          <<< 
increased RBUF from 15 to 20
         MSCOPE(*) 


  My suspicion was console buffer overflow as the 3174 wasn't in the mix 
any more. Lucky guess? I'll take luck...