Eureka!
CONSOLE DEVNUM(D907) UNIT(3277-2) /* MCONS -- ICC D907 */ <<<
set unit from 3270-X to 3277-2
NAME(DEVOSC04) AUTH(MASTER) USE(FC) ROUTCODE(ALL)
ALTGRP(DEVOSALT) CON(N) DEL(RD)
RNUM(13) SEG(14) AREA(NONE) RTME(1/4) MFORM(J,T)
PFKTAB(PFKTAB00)
MONITOR(JOBNAMES-T,SESS-T) LEVEL(ALL) RBUF(20) <<<
increased RBUF from 15 to 20
MSCOPE(*)
My suspicion was console buffer overflow as the 3174 wasn't in the mix
any more. Lucky guess? I'll take luck...
Daniel McLaughlin
ZOS Systems Programmer
Crawford & Company
PH: 770 621 3256
"If we wait for the moment when everything is ready, we shall never
begin."
? Ivan Turgenev
----------------------------------------------------------------------