Bruce,
   
  Got around all of this by backing up the IODF from the test lpar and 
restoring it to the production lpar.
   
  This was just needed to do a software OS config for the Prod Lpar and worked 
as it should.
   
  Thanks.
  

Bruce Black <[EMAIL PROTECTED]> wrote:
  >
> The problem is that on both lpars the master catalogs are the same names and 
> the datasets on the test lpar are in the master catalog.
Its probably a bad practice to use duplicate master catalog names. make 
each one unique so they can be accessed by the opposite system.

To solve your problem, I suggest backing up the clusters on the test 
LPAR, deleting them, and restoring them to new names which would put 
them in a shared catalog.

-- 