The JES2 spool is not a multi-volume dataset. Rather, it is a collection
of individual single-volume datasets, each residing on a different volume.
JES2 Initialization and Tuning (zOS 1.4 and 1.7 both) state acceptable
values for SPOOLNUM are in the range from 1 to 253, inclusive.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
This is a PRIVATE message. If you are not the intended recipient, please
delete without copying and kindly advise us by e-mail of the mistake in
delivery. NOTE: Regardless of content, this e-mail shall not operate to
bind CSC to any order or other contract unless pursuant to explicit written
agreement or government initiative expressly permitting the use of e-mail
for such purpose.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Ted MacNEIL
<[EMAIL PROTECTED]
ca> To
Sent by: IBM [email protected]
Mainframe cc
Discussion List
<[EMAIL PROTECTED] Subject
.EDU> Re: RES: JES2 SPOOLDEF
08/18/2006 03:01
PM
Please respond to
[EMAIL PROTECTED]
a
>SPOOLNUM=64
Considering you can only get 59 volumes on a multi-volume dataset 64
doesn't make sense.
When in doubt.
PANIC!!
----------------------------------------------------------------------