Open a PMR to have the PTF PE'd. The fixing APAR should be repackaged with the correct IF REQ's. If level 2 will not do this, escalate to the duty manager.

Regards,
Tom Conley

----- Original Message ----- From: <[EMAIL PROTECTED]>
Newsgroups: bit.listserv.ibm-main
Sent: Monday, August 21, 2006 9:40 AM
Subject: SMP/E ++HOLD ERROR for Cross-FMID Requirement


What is the correct process when a SYSMOD is discovered post-release
to have a corequisite in a FMID other than its own?  Is the developer's
only recourse to create a dummy PTF to bear the ++IF ... REQ for the
SYSMOD in the other function and let that resolve a ++HOLD ERROR?


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to