Open a PMR to have the PTF PE'd. The fixing APAR should be repackaged with
the correct IF REQ's. If level 2 will not do this, escalate to the duty
manager.
Regards,
Tom Conley
----- Original Message -----
From: <[EMAIL PROTECTED]>
Newsgroups: bit.listserv.ibm-main
Sent: Monday, August 21, 2006 9:40 AM
Subject: SMP/E ++HOLD ERROR for Cross-FMID Requirement
What is the correct process when a SYSMOD is discovered post-release
to have a corequisite in a FMID other than its own? Is the developer's
only recourse to create a dummy PTF to bear the ++IF ... REQ for the
SYSMOD in the other function and let that resolve a ++HOLD ERROR?
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO