Bingo but not as suggested

MODIFY COMMAND PER ... gives HCPZPM770E MODIFY is not valid for command PER

But

 MODIFY COMMAND DUMP SILENTLY
then
PER DIAG 58 PRINTER CMD SILENTLY DUMP 0.20;BASE3

Gives desired results

Thank You


Tom Schmidt wrote:
Have you explored the MODIFY COMMAND xxxxx SILENTLY command yet? You have to modify the command (via the MODIFY COMMAND command) and then issue your 'PER DIAG 58 PRINTER CMD DUMP 0.20;BASE3' command as: 'SILENTLY PER DIAG 58 PRINTER CMD DUMP 0.20;BASE3' instead. It is in the z/VM 5.1 CP Commands and Utilities documentation.

--
Chris Langford,
Cestrian Software:
Consulting services for: VM, VSE, MVS, z/VM, z/OS, OS/2, P/3x0 etc.
    z/FM  - A toolbox for VM & MVS at http://zfm.cestrian.com
Deva Woodcrafting:
    Furniture creation, House remodeling, Wagon restoration etc.

----------------------------------------------------------------------