Haven't yet had this happen on our 3590s, but have had similar problems
with channel interfaces on 3490 controllers.
The solution with 3490s was was to get devices/CHPIDs off line to all
systems and re-IML the tape controllers with the correct interfaces
enabled, then put things back on line to MVS. The 3490 controllers
would get in a state where they simply wouldn't re-enable the channel
interfaces without an IML.
[EMAIL PROTECTED] wrote:
Yep...all them options. Just IPL'd the sandbox to see could we get them up
there. Same results.
Daniel McLaughlin
Z-Series Systems Programmer
Crawford & Company
4680 N. Royal Atlanta
Tucker GA 30084
phone: 770-621-3256
fax: 770-621-3237
email: [EMAIL PROTECTED]
web: www.crawfordandcompany.com
...
"Neubert, Kevin (DIS)" <[EMAIL PROTECTED]>
Sent by: IBM Mainframe Discussion List <[email protected]>
11/09/2006 11:36 AM
Please respond to
IBM Mainframe Discussion List <[email protected]>
To
[email protected]
cc
Subject
Re: All Boxed Up
"...varied with various forms of vary..."
Including VARY device(s),ONLINE,UNCOND?
Regards,
Kevin
...
--
Joel C. Ewing, Fort Smith, AR [EMAIL PROTECTED]
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO