Hi all,

Many thanks to all that replied this message. In fact I confirmed (manuals
and IBM ETR) that the usage of GRS is mandatory to add a new system to an
existing sysplex, and because of this my boss is not happy at this moment,
but I found in that a system using the GRSRNL=EXCLUDE parmlib parameter can
be added to an existing sysplex (see details below). 

Anyone is using this type of configuration? There is any alternate
suggestion for this approach? 

Thanks in advance,

Morelatto
T-Systems Brazil

>From the "z/OS V1R4.0 MVS Setting Up a Sysplex", page 18:

GRSRNL=EXCLUDE indicates that all global enqueues are to be treated as local
enqueues. All ENQ macro requests are excluded from global serialization and
are serialized locally; except that all resources identified on an ENQ
SCOPE=SYSTEMS,RNL=NO macro are globally serialized on all systems in the
complex.

Use GRSRNL=EXCLUDE when you do not have an existing global resource
serialization complex, are adding the system to a sysplex, and want the
serialization of most resources done with the RESERVE macro.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html