Hello,

I have a little ghost between JES2 conversion and WLM inits...

Once upon a time... a system (SYS2) was IPLed, it lived in a sysplex and it 
had some WLM inits.

IPL automation executed "$PXEQ" and four secs later appeared "*$HASP222 XEQ 
DRAINING". All seemed correct. Then, IPL automation continued. 15min later 
was executed "P TSS" and 6secs later the TSS ended.

But... the scheduler of this sysplex (started in another system) continued 
sending jobs (without affinity) to execution and one of them was sent to 
IPLed system. ¿?. Then, the specified job was cancelled because JES2 
couldn't create the security environment for the job to be converted due to 
TSS had been stopped.

So, the problem seems to be related to job conversion phase. 



Chronology:
===========

SYS2 04:00:50.71 BB200000 $PXEQ 

SYS2 04:00:54.54          *$HASP222 XEQ DRAINING

SYS2 04:15:05.76 BB200000 P TSS    

SYST 04:15:11.47 JOB20327 $HASP100 IMED7401 ON INTRDR FROM STC11701

SYS2 04:15:11.54 JOB20327 TSS7181E End of Day - No Further System Access 
Allowed 

SYS2 04:15:11.55 JOB20327 $HASP313 IMED7401 JES2 IS UNABLE TO CREATE THE 
SECURITY ENVIRONMENT SECURITY PRODUCT RETURN CODE = 0000001C REASON CODE = 
00000000          

SYST 04:15:12.47 JOB20327 $HASP250 IMED7401 PURGED





Thanks in advance
Regards
Chr. Blesa

----------------------------------------------------------------------