The syntax for MARKFULL is in the DELVOL section of the "HSM Storage
Administration Reference" manual.  But my manual says that this makes
the tape eligible for recycling which seems redundant since it is
already being recycled (unsuccessfully).

I think what you really want is RECYCLE with EXECUTE and FORCE.  This
will allow HSM to salvage as many files as possible while ignoring the
ones with data checks.  Since you cannot recover the files with data
checks anyway, they are already lost.

-----Original Message-----
From: John Dawes [mailto:snip] 
Sent: Thursday, December 14, 2006 11:36 AM
To: [email protected]
Subject: [SPAM] DFHSM - BAD TAPE - U R G E N T

Hallo To all
   
  I am having a Dickens' of a time trying to solve this problem.  DFHSM
is trying to recycle a tape and it cannot read it because of datachecks.
I performed a CANCEL REQUEST and got it out of the system.  However, I
was told that DFHSM will try again to recycle that damaged  tape again.
I checked the doc and I saw that the MARKFULL could bail me out.  One
problem is that I do not know how to code the syntax.  Can anybody
advise me?

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html