In article <[EMAIL PROTECTED]> you wrote: > I'm working on a little problem. I have an SVCDUMP that contains more > than one address space. I have a LARGE exec library for diagnosing > various things.
> > The problem is, I just can't seem to establish the ASID to be used for > addresses, C/Bs, etc. > > Would anyone have a quick hint on how to convince a CLIST or REXX which > address space I am trying to process? I have tried to set (from the > defaults panel) the asid I want, but that doesn't seem to cut it. And so > far, trying to specify ASID on commands hasn't worked too well. > > I am trying to RTFM and look at IBM's supplied REXX/CLIST for IPCS, but > obviously I'm missing something. > > If I don't respond for about a day, its because I've finally crashed > from exhaustion (end of year stuff that has to be done so QA will bless > a product release). > > Later, > Steve Thompson Try setting the asid at the option 0 screen, then go into browse and insert a new bookmark (use the 'i' line command). Select that new line and you should then be looking at the correct address space. Run the exec while browsing that space and it should work. -- Don Poitras - SAS Development - SAS Institute Inc. - SAS Campus Drive [EMAIL PROTECTED] (919) 531-5637 Cary, NC 27513 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html