I can never recall waiting for the system to enter a wait state before
performing a system reset.  I also don't do the 'Z EOD' as is
recommended.  I guess I was asking for it.

I run with a CLEANUP interval of 180 (3 minutes) so I could have to wait
that long prior to system reset.  Seems kind of long to me now that I
think about it.


From:  JamesChapp

Hummm.. 
Removing a z/OS system from a Sysplex -- 
http://www-03.ibm.com/systems/z/pso/removing.html#ton2 

Complete the removal of the z/OS system manually: 
Shortly after replying to message IXC371D in step 3, message IXC102A 
will be displayed. 

DO NOT REPLY "DOWN" TO IXC102A YET. 

Wait for the z/OS system to enter a non-restartable WAIT state. The z/OS

system should enter a non-restartable WAIT state any time before or soon

after the CLEANUP interval expires. 

Perform a hardware SYSTEM RESET on the z/OS system being removed from 
the sysplex if not already done. 

Reply "DOWN" to IXC102A. Message IXC105I will be issued when system 
removal is complete. 

Are WE saying this isn't correct? 

 

----------------------------------------------------------------------