Didn't Dave mention the Dataclass assignment had SCR=YES and a DVC=10? If so, he already has a 10 volume candidate list.
Terry Traylor charlesSCHWAB TIS Mainframe Storage Management Remedy Queue: tis-ds-mainframe storage (602) 977-5154 WARNING: All email sent to or from this address will be received by the Charles Schwab corporate e-mail system and is subject to archival and review by someone other than the recipient. -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Phil Sidler Sent: Friday, December 22, 2006 1:11 PM To: IBM-MAIN@BAMA.UA.EDU Subject: Re: Max Allocation w/ Space= DD On Fri, 22 Dec 2006 14:52:29 -0500, Dean Montevago <[EMAIL PROTECTED]> wrote: >Can anybody comment on this: I specify 4000/4000cyl and z/OS allocates >1/4000cyl. The info you guys provided has been very helpful but I don't >understand why I'm getting this.... It sounds like the dataset has used the 1st 4000 cylinders and needs to go into a secondary extent. Another 4000 cylinders takes the dataset past the 65525 trks/volume limit for normal datasets. You could try using more volumes, for example UNIT=(SYSDA,2) ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html