Mark -
      That is what we do, when we clone to new targets aprox once a month
for RSU. We have a two sysres set. On the second target volume we rebuild
SAD, this way we know its happening if it needs it or not. Something we
adopted a while back. Then IPL from the SAD pack from our lab system to
verify it works. But was wondering if I can tell from an eye catcher if
maint was picked up for it. I assume not if i'll only find it in hold data,
which we do review.

      Thanks

Andy
Internet: Mailto:[EMAIL PROTECTED]


"
> > We put on monthly RSU then we rewrite the SAD
> >information to our volume in hopes to pick up new maintenance is this
not
> >needed to do?
> >
>
> You only need to rebuild SAD if there is a specific ++ACTION HOLD
> telling you to do so.
>
> I guess you can rebuild it every time to make sure you never miss
> the action hold, but I hope you don't put on maintenance and ignore
> action holds as a matter of habit.  I also wouldn't rebuild it every
> time you put on maintenance unless you also include IPLing it
> afterwards to verify it is functioning. But that's just me...
>
> Mark
> --