I'm trying to build an IOCDS in preparation for upgrade from a z/890 to a z9
business class (D/T 2096). I'm getting a message (ICP150I) I can't seem to
locate. I suspect that IOCP doesn't recognize D/T 2096, even though I've
pulled the PSP buckets and applied the atypically modest amount of recommended
maintenance.
STATEMENTS PROCESSED BY ICP IOCP VERSION 1 RELEASE 3.0
ID MSG1='A2IODF01',MSG2='SYS2.IODF01 - 2007-01-02 14:53', *
SYSTEM=(2096,1), *
TOK=('P007500E',00800002A8EF2086145342170107002F00000000*
,00000000,'07-01-02','14:53:42','SYS2','IODF01')
ICP150I INVALID SYSTEM PARAMETER
RESOURCE PARTITION=((CSS(0),(BEST,2),(PROD,1),(TEST,4),(Y2K,3)*
)),MAXDEV=((CSS(0),16384,0))
ICP115I DELIMITER ERROR, EXPECT RIGHT PARENTHESIS - ,0))
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html