Matthew,
        I tried to keep the initial post small, believe it or not, and 
left out a lot of detail, so the answer is YES - I think.

My recollection is that when we explicitly vary the drives offline for 
maintenance they are always varied offline to ALL LPARs in the SYSPLEX. In 
Production that is 2 LPARs, and we do not share drives across SYSPLEXes 
(at this particular location), so each SYSPLEX has only it's own devices 
genned. 
Similarly, when there is an 'error', we see the devices being implicitly 
varied offline to all LPARs automatically on the SYSLOG. 

We had a recurrence of the issue today (hence my post) and I see from the 
the SYSLOGs that in this particular case we had an error, the drive was 
varied offline to both LPARs automatically, and somebody then varied the 
drive back online to only one of the LPARs (LPAR2) but not the other 
(LPAR1) where we saw the problem this morning.
However, we have previously had occasions where the error went unnoticed 
and drive has remained offline to both LPARs and the problem manifested 
itself in exactly the same way.

I am interested to know the reason behind your (not stupid at all) 
question. 

Steve O.

----------------------------------------------------------------------