David,

In IPCS option 0, set the source to "active" and then enter

ip l 10?+c8?+84?+d0? str l(512)

This will show you who's actually handling SVC 26 (it's CVT->SVCT->SVCTABLE->entry for SVC 26->entry point).

ip l 10?+c8?+88?+270? str l(512)

will show who was previously handling SVC 26 (it's ...SVC recording table->entry for SVC 26...). If this isn't the IBM module,

ip l 10?+c8?+88?+284 l(2)

will show the number of updates to SVC 26 (from the SVC recording table entry).

Bob

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to