Dennis Trojak wrote:
Have you checked the ROUTCODE setting for SYSCONS?
Dennis
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED]
Behalf Of Hal Merritt
Sent: Wednesday, January 31, 2007 11:33 AM
To: [email protected]
Subject: Console issue (was SAE and SAR with Visara)
I use that feature, but am very unhappy with the result. It seems a
*lot* of messages are not displayed making it darned difficult to
diagnose a failing IPL.
Any idea what I might be doing wrong? I have no consoles defined in the
IODF, forcing NIP messages to the HMC. That works ok, but when NIP hands
off control to MVS, many MVS and JES messages just don't appear.
Another thought, do you have an AUTOACT group setup so the HMC will
be automatically activated when there are no other available consoles?
--
Richard
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html