On Wed, 31 Jan 2007 16:04:00 -0600, Mark Zelden <[EMAIL PROTECTED]> 
wrote:

>...
>Someone else told me they have seen the problem - but only when
>a CEC was down for hardware changes and other LPARs IPLed.  But
>many LPARs being IPLed at different times is SOP during scheduled
>outage windows once a month.
>...

That would make sense if the active/passive relationship were determined
when the hardware initialized rather than at IPL time.  Unfortunately
we try to keep one CEC (CPC now, I think) up whenever we do a POR so we
would occassionally run into this.   All we have to do to avoid it is
make sure our PORs are timed to happen simultaneously and finish within
milliseconds of each other.  