Oops...it now works!!!!!! John,
If you specify the workstation CP name the same as the PU name, the connection will fail. I have tried with that. Of course, just as Chris said, the local LU 6.2 name can be the same as the CP name. Yes. The DEFAULTAPPL statement is the cause of all these problems - When I added it to the initialization file, both EEDLC and Anynet works!!! I must say here that the APP3270 manuals are really not so friendly. They told me that APP3270 is modelled after TN3270 server and they didn't told me that unlike TN3270 server APP3270 server must have a default application choosed. (And that's why I commented that statement out in the ini file.) Thanks, Chris and John. I'm now feeling very good and without your help, it's impossible. On 2/26/07, Johnny Luo <[EMAIL PROTECTED]> wrote:
On 2/25/07, John S. Giltner, Jr. <[EMAIL PROTECTED]> wrote: In the "IST663I INIT OTHER REQUEST FAILED, SENSE=10010008 256" message, what are the LU names invloved? Ya..here is the problem. I don't know how to find out and the only thing I can do is to look up the sense code but sadly it's of little help. As I said in the previous mail, when connecting through Anynet, the problem is the same.. -- Best Regards, Johnny Luo