ADR374E (001)-OPNCL(09), UNABLE TO OPEN DDNAME TAPE, 10
10   Invalid parameters passed in JCL. The following are the probable
reasons: o SYSIN/SYSOUT data set o DISP=MOD coded for the output data set o DISP=SHR coded for the output data set o BLKSIZE less than 7892 bytes o DSORG other than PS o BUFNO specified. Please show us your JCL.
--
Bruce A. Black
Senior Software Developer for FDR
Innovation Data Processing 973-890-7300
personal: [EMAIL PROTECTED]
sales info: [EMAIL PROTECTED]
tech support: [EMAIL PROTECTED]
web: www.innovationdp.fdr.com

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html