-------------------------<snip>-----------------------------------

can one of you gurus out there please shed some light on this, since i
am not sure what the answer should be or whether or not this is normal,
since

these jobs supposedly have been running and working for the last 20
years (although i am not sure if they ever ran at the same time).
------------------------------<unsnip>----------------------------
MVS does a ENQ on the GDG base, to asure that the generation number doesn't change. This ENQ is not released until the job completes.

They may have been running for 20+ years, but not simultaneously. This behaviour hasn't changed since dirt was new.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to