-------------------------<snip>-----------------------------------
can one of you gurus out there please shed some light on this, since i
am not sure what the answer should be or whether or not this is normal,
since
these jobs supposedly have been running and working for the last 20
years (although i am not sure if they ever ran at the same time).
------------------------------<unsnip>----------------------------
MVS does a ENQ on the GDG base, to asure that the generation number
doesn't change. This ENQ is not released until the job completes.
They may have been running for 20+ years, but not simultaneously. This
behaviour hasn't changed since dirt was new.
----------------------------------------------------------------------