In <[EMAIL PROTECTED]>, on 04/11/2007
at 02:30 PM, willie bunter <[EMAIL PROTECTED]> said:
>We are having a difference of opinion with the following issue. A
>gener job is failing on an IEC145I 413-08. My interpretation is that
>the job failed because of an I/O error. The other opinion is that
>because the tape is scratch (in RMM) and it does not permit the
>processing of a scratch tape. Can we both be right?
No. Had there been an I/O error then there would have been a message
with the CSW status and the sense data.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO position; see <http://patriot.net/~shmuel/resume/brief.html>
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)
----------------------------------------------------------------------