Hi,

Products that measure LPAR activity may get an ABEND or bad data due to bad 
data in the LCCA control block. We saw this with CA-SYSVIEW (ABEND S0C9) and 
IBM APAR OA19440 was recommended. 

OA19440 LCCAWTIM INVALID LARGE NEGATIVE VALUE - X'FF0 0XXXX XXXXXXXX'

http://www-1.ibm.com/support/docview.wss?uid=isg1OA19440 

IMHO while the IBM APAR is good anyone fishing in the LCCA should be prepared 
to clean whatever they catch :-) 

        Best Regards, 