Sorry to put in a plug for a vendor product but ACC from DTS Software can let you select the device or range of devices that you want.
www.DTSsoftware.com  or [EMAIL PROTECTED]

Duane Reaugh
DTS Software
919 833 8426 x123


On May 18, 2007, at 8:31 AM, Bruno Sugliani wrote:

On Fri, 18 May 2007 14:05:23 +0200, Vernooy, C.P. - SPLXM
<[EMAIL PROTECTED]> wrote:
Hello list,
We have a TS7700 VTS in a grid Configuration, which consists of 2 TS7700
clusters each with its own tapeunits, coupled together as one VTS with
two distributed libraries as seen by SMS. Since it is one VTS to SMS,
SMS will select a random tapeunit from the total pool of devices.
Normally this is no problem.
However, if I want tot read statistics from each cluster's library
manager, I must address a device from that specific cluster. Since SMS
considers it one VTS, I have not been able to force my allocation to an address of the desired cluster. I tried a unitaddress, created generics
for each cluster and used them, but no success.
Cluster 0 has devices 0600-06FF, cluster 1 has devices 0700-07FF. How
can I force an allocation to a device of the desired cluster?


Exactly the same here .
We faced the same problem , I'll ask if my colleague found a way , she was
working on it
Bruno
Bruno(dot)sugliani(at)groupemornay(dot)asso(dot)fr


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to