Hi John! We thought that the default tape BLKSIZE has been changed to 65k 
from 32k in zOS 1.4. Our DR site which has an older zOS can not read the 65k 
BLKSIZE tapes. We want to write the tapes at 32K.

My latest research into the problem shows that APAR OA13742 changed the 
way the output tape is written and puts the actual Blocksize in the tape label. 
It used to be 0.

My issue is that the exit (ADRUIXIT) would work for JCL driven ADRDSSU 
invocations but not from HSM invocations.

Hope that explains why  

----------------------------------------------------------------------