L.

What he said PLUS check for AMODE/RMODE of any recent changes.

Bill


From: "Clark, Kevin" <[EMAIL PROTECTED]>
Reply-To: IBM Mainframe Discussion List <[email protected]>
To: [email protected]
Subject: Re: CICS Abends at startup AKEA
Date: Tue, 5 Jun 2007 15:40:45 -0400

L.

A dump would be better than a guess, however DFHLUP is for LU services/
MRO. Perhaps you have a 24bit program trying accessing EDSA.

Do a CEMT I SYD

RESULT - OVERTYPE TO MODIFY
  Sydumpcode(SR0001)    --------check the AP0001 also
  Sysdumping( Nosysdump )
  Dumpscope( Local )
  Shutoption( Noshutdown )
  Maximum( 003 )
  Current(0000)
  Action(              )
  Daeoption( Nodae )


Kevin

----------------------------------------------------------------------