L.
What he said PLUS check for AMODE/RMODE of any recent changes.
Bill
From: "Clark, Kevin" <[EMAIL PROTECTED]>
Reply-To: IBM Mainframe Discussion List <[email protected]>
To: [email protected]
Subject: Re: CICS Abends at startup AKEA
Date: Tue, 5 Jun 2007 15:40:45 -0400
L.
A dump would be better than a guess, however DFHLUP is for LU services/
MRO. Perhaps you have a 24bit program trying accessing EDSA.
Do a CEMT I SYD
RESULT - OVERTYPE TO MODIFY
Sydumpcode(SR0001) --------check the AP0001 also
Sysdumping( Nosysdump )
Dumpscope( Local )
Shutoption( Noshutdown )
Maximum( 003 )
Current(0000)
Action( )
Daeoption( Nodae )
Kevin
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
_________________________________________________________________
PC Magazines 2007 editors choice for best Web mailaward-winning Windows
Live Hotmail.
http://imagine-windowslive.com/hotmail/?locale=en-us&ocid=TXT_TAGHM_migration_HM_mini_pcmag_0507
----------------------------------------------------------------------