Where did you see this?  I only found...

5.13.1.1.3 Transmitting unsupported data types

You can use TRANSMIT to send sequential or partitioned data sets with record formats of F, FS, FB, FBS, V, VB, VBS, and U. Data sets with machine and ASA print-control characters are also supported. Data sets with keys or labels, and ISAM and VSAM data sets are not. RECEIVE can process data
from TRANSMIT and PROFS.

...in the z/OS 1.8 book.

Bob


Kenneth E Tomiak wrote:
From my reading in TSO/E Customization, TRANSMIT makes the call to
IEBCOPY if you process a DSORG=PO type of dataset and Access Method Services REPRO if you process a VSAM dataset. No need for an extra step to flatten VSAM. Sounds like something to try after I finish rewriting my PC DOS 7.0 REXX receive code.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html