Hello:  Shortly after upgrading to v1.7, but not necessarily connected to that 
migration, one of our busier systems experienced a number of IEE178I 
messages during heavy batch processing. 

We added to IEAOPTxx:  mccafcth=(4000,4500) 
varying the actual numbers (our capacity planning tech made the 
recommendations).  See apar OA12185 for the explanation.  There was no 
outage but the messages alerted the operators.  regards, Joe D'Alessandro

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html