On Wed, 27 Jun 2007 12:36:37 +0200, R.S. <[EMAIL PROTECTED]> wrote: >STK tape environmnet, HSC and VTCS at level 6.1 > >Due to drive error an MVC tape was damaged. It was manually removed by HW enigeneer. >Fortunately all the VTVs are written in two copies - another MVC exist (in another ACS in another location). > >Q: how to 'fix' it ? >I mean: >1. To tell VTCS and HSC the tape is no longer available. >2. To re-create second copy of VTVs which are now on single media. > >I did some RTFM and think I should simply MVCDRAIN. >
This is part of the normal DR process to return off-site tapes. But it also applies to any MVC that can be rebuilt if the VTVs are duplexed. 1) Mark it lost 2) MVCDRAIN Draining will then recall all the VTVs from the alternate MVCs and re-migrate them to new ones. Once the "bad" MVC is drained, you can replace it (initialize, audit, etc.). Mark -- Mark Zelden Sr. Software and Systems Architect - z/OS Team Lead Zurich North America / Farmers Insurance Group: G-ITO mailto:[EMAIL PROTECTED] z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/ Systems Programming expert at http://expertanswercenter.techtarget.com/ Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html