I already answered Anton in another post but I wanted to respond to this and make clear that DFSORT work files cannot span multiple volumes. If you coded UNIT=(SYSDA,10) on a SORTWKnn DD statement, DFSORT would still use only 1 volume for each SORTWK data set.
Have a nice day, Dave Betten DFSORT Development, Performance Lead IBM Corporation email: [EMAIL PROTECTED] 1-240-715-4655, tie line 268-1499 DFSORT/MVSontheweb at http://www.ibm.com/storage/dfsort/ IBM Mainframe Discussion List <[email protected]> wrote on 07/01/2007 02:10:23 PM: > >If necessary and the file is SMS managed add a volume parameter to > the UNIT parameter, eg. UNIT=(SYSDA,10). > > It doesn't have to be SMS managed for the volume parameter to work. > - > Too busy driving to stop for gas! > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html