In a message dated 7/17/2007 8:09:13 A.M. Central Daylight Time,  
[EMAIL PROTECTED] writes:

Seems  like there is no physical connection, or an interface is  disabled.



>>
DS QT,1500,16,validate
 
Used to have an A22 and every now and then one of the controller's power  
supplies would fail. No errors or anything just adios. So first thing is check  
the green lights on the back of the unit. If they're ESCON check the 
connections  on the front.
 
Run EREP.
 
Call for service.