In <[EMAIL PROTECTED]>,
on 07/11/2007
   at 12:51 PM, Sarel Swanepoel <[EMAIL PROTECTED]> said:

>I dumped the full volume using the tracks option and restored it on
>an empty volume on our test system. I located the PDS at location

> 

>** TRACK(CCHH)  1A580000         R0 DATA  0000000000000000


>   COUNT  1A580000010005A0

R0 is irrelevant for a PDS. Does R1 have a key length of 8 and a data
length of 256? If not, you don't have a directory there.

>When I used this as the track address I am getting a JCL error.

Yes, ABSTR is limited to 64KiB-1.

> I am also confused with what I checked in the JCL manual. The 
>manual says that the primary space allocation is in tracks and not 
>cylinders 

what manual, where, for what context? The primary quantity can be in
any units supported by the SPACE keyword of DD, one of which is ABSTR.
In the case of ABSTR there is no provision for a secondary quantity. 

-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     ISO position; see <http://patriot.net/~shmuel/resume/brief.html> 
We don't care. We don't have to care, we're Congress.