On Thu, 26 Jul 2007 09:20:38 -0400, Andy White <[EMAIL PROTECTED]> wrote:
>We have the same definition I wonder if its the Attachmate or Bluezone >sessions we have set up neither works, they work as a tn3270 (meaning I >can get a vtam10 screen and logon) but as console it gets the error. >Andy Andy - I am assuming the ICC definition did not change? I am not adversed with OSA-ICC's as our first expirence with them was when we put in our z9. Not sure if the definition files are the same from a z8 to a z9, but in either case, here is what the definition looks like for one of our consoles: <CONFIG_SESSION> <SESSION1> CSS= 00 IID= 01 DEVICE= 1900 GROUP= "PRODCON1" CONSOLE_TYPE= 2 RESPONSE= ON READ_TIMEOUT= 10 </SESSION1> The TSO sessions in my definition are set to a type of "1": <SESSION6> CSS= 00 IID= 01 DEVICE= 1905 GROUP= "PRODTSO1" CONSOLE_TYPE= 1 RESPONSE= ON READ_TIMEOUT= 10 </SESSION6> We use Attachmate here and set up was not any different than on a 2074. We have our Display settings set to "Any Model" for our consoles and it works fine. HTH, PTL ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html