On Mon, 6 Aug 2007 06:55:07 -0500, Chase, John <[EMAIL PROTECTED]> wrote:
>Might it also be possible that having a UNI= in parmlib "drove the >requirement" to have SCUNIMG in the linklist? > No. If you have UNI=, then you are taking the image from a parmlib member. SCUNIMG came in later via APAR. None of our systems had it for a long time. When we migrated to z/OS 1.6 it was added to most systems by the person who did the migration (even though we still didn't require it for anything). >Anyway, based on the z/OS Unicode Services manual (for 1.7; haven't seen >one with that title in the 1.8 bookshelves) I added SCUNIMG to the >linklist and APF list in the LPAR where DB2 v8.1 is first going to be >installed (still no UNI= in parmlib yet). I think that is a good idea. >It also appears that, for our >installation anyway, we might be able to "pare down" the pre-built DB2 >image significantly. > Unless real storage is a big problem in your shop, I see no reason to do so. See my last post... -- Mark Zelden Sr. Software and Systems Architect - z/OS Team Lead Zurich North America / Farmers Insurance Group - ZFUS G-ITO mailto:[EMAIL PROTECTED] z/OS and OS390 expert at http://searchDataCenter.com/ateExperts/ Systems Programming expert at http://expertanswercenter.techtarget.com/ Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html

