The responses to my impatient post have reinforced my uncharitable view of this thread. See


Note: At the start of execution, RC is initially set to zero.

stepname.RC Indicates that the relational-expression tests a return code for a specific step
(stepname) of the job.

stepname.procstepname.RC Indicates that the relational-expression tests a return code for a specific step (stepname) and procedure step (procstepname) of the job.


on page 17-5 of z/OS MVS JCL Reference, SA22-7597-11.

Unambiguous reference to any <jobstepname>.<procstepname> value is supported in IF-THEN-ELSE-ENDIF statements that test RC values.

Note also that Paul Gilmartin's anxiety about the initial, i.e., start-of-job, return-code (RC) value, while it has a basis in formal logic, is gratuitous here.

John Gilmore
Ashland, MA 01721-1817
USA

_________________________________________________________________
Messenger Café — open for fun 24/7. Hot games, cool activities served daily. Visit now. http://cafemessenger.com?ocid=TXT_TAGHM_AugHMtagline

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to