Howard,

Then the REFORMAT in ICKDSF will change a VOLSER without disrupting any
data on the volume.  But as David pointed out, relabeling the VOLSER
will definitely break all your catalog pointers to data on that volume.
In addition, although I don't know if this will actually break anything
or just be a cosmetic thing, but the VVDS and/or VTOCIX datasets will
not be renamed to reflect the new volser.  

Rex

________________________________

From: Howard Rifkind [mailto:[EMAIL PROTECTED]
Sent: Tue 8/14/2007 6:15 PM
To: [email protected]
Subject: Re: ICKDSF Intilize question.



Rex, no, all I want to do is change the volser on this volume.

Reason.  A long time ago some genius here decided to have volumes on
both the test and prod volume the same.  Go Figure!

----------------------------------------------------------------------