Howard, Then the REFORMAT in ICKDSF will change a VOLSER without disrupting any data on the volume. But as David pointed out, relabeling the VOLSER will definitely break all your catalog pointers to data on that volume. In addition, although I don't know if this will actually break anything or just be a cosmetic thing, but the VVDS and/or VTOCIX datasets will not be renamed to reflect the new volser.
Rex ________________________________ From: Howard Rifkind [mailto:[EMAIL PROTECTED] Sent: Tue 8/14/2007 6:15 PM To: [email protected] Subject: Re: ICKDSF Intilize question. Rex, no, all I want to do is change the volser on this volume. Reason. A long time ago some genius here decided to have volumes on both the test and prod volume the same. Go Figure! ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html