Hi,

An update from IBM:

I found the caller of SMS was IDCAMS module IDCSA11 +x'24D4' base z/OS
1.7. The data shows they passed in a unit of all zeros in the control
block known as the ACERO. I verified that your ALLOCxx and your SMS base
configuration had a default unit so I would think something should have
been filled in. To help out IDCAMS I would like to show them the change
in behavior by attempting to recreate on my end. I would like to see the
IDCAMS define statement you used. I'll slip at the same exact point on
my test system for z/OS 1.4 and z/OS 1.7 to provide them the
documentation to continue analysis on the change of behavior.

Regards,
Dean
 



----------------------------------------------------------------------