On Mon, 10 Sep 2007 17:01:49 -0500, George Dranes wrote:

>We only use 2 exits in JES2 so I've always just re-assembled these after
>maintenance has been applied.  I was wondering if anyone has an easy way of
>using SMP/E to apply these if maintenance changes the JES2 macros?  I'm just
>not real handy creating usermods.  The 2 exits we use are HASX01B and
>HASX15A.  Thanks for any help!
>
I believe that if you code the exits as instream SYSIN in JCLIN
MCS, they will automatically be rebuilt when any macro in the
same zone is changed.

-- gil

----------------------------------------------------------------------