I am trying to pull an RMF Post Processor report for CF paths.

I have the following control cards with the following message:

ERB103I PPS: OPTIONS IN EFFECT                                    
ERB103I PPS:   SYSOUT(R)  -- SYSIN                                
ERB103I PPS:   REPORTS(XCF)  -- SYSIN                             
ERB103I PPS:   MAXPLEN(050)  -- SYSIN                             
ERB103I PPS:   NOEXITS  -- SYSIN                                  
ERB103I PPS:   NODELTA  -- SYSIN                                  
ERB103I PPS:   SUMMARY(TOT)  -- SYSIN                             
ERB103I PPS:   SUMMARY(INT)  -- SYSIN                             
ERB103I PPS:   STOD(0000,2400)  -- SYSIN                          
ERB103I PPS:   RTOD(0000,2400)  -- SYSIN                          
ERB103I PPS:   PTOD(0000,2400)  -- SYSIN                          
ERB103I PPS:   ETOD(0000,2400)  -- SYSIN                          
ERB103I PPS:   DATE(07252007,07252007) -- SYSIN                   
ERB106I PPS: NO SMF RECORDS FOUND FOR FOLLOWING OPTION(S)         
ERB106I PPS:   REPORTS(XCF), SMF RECORD 74 - SUBTYPE 2  

Does this mean I do not have collection turned on for this particular report?  
If not, what do I need to turn on in RMF to collect them?

Our shop typically collects all SMF records adnasum.