>> I am in a quandry. A user has asked that a PDS not be migrated because it is a huge file (about 2,500 cylinders). >> I was able to satisfy his requirement, however, the MANAGEMENT CLASS which governs it has no backup attributes >> (client didn't want a backup) by DFHSM but the user wants a backup of the dsn. I think my only choice I have is to >> define the dsn in another MANAGEMENT Class and have DFHSM attributes for a backup done. Could there be another >> solution to my problem? Maybe I'm missing something here & maybe this is too simplistic, but why not create a managment class with the correct attributes and use the IDCAMS ALTER command alter the command for the existing dataset? ************************************************************************************** This e-mail message and all attachments transmitted with it may contain legally privileged and/or confidential information intended solely for the use of the addressee(s). If the reader of this message is not the intended recipient, you are hereby notified that any reading, dissemination, distribution, copying, forwarding or other use of this message or its attachments is strictly prohibited. If you have received this message in error, please notify the sender immediately and delete this message and all copies and backups thereof.
Thank you. ************************************************************************************** ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html