>>  I am in a quandry.  A user has asked that a PDS not be migrated 
because it is a huge file (about 2,500 cylinders).  >> I was able to 
satisfy his requirement, however, the MANAGEMENT CLASS which governs it 
has no backup attributes 
>> (client didn't want a backup) by DFHSM but the user wants a backup of 
the dsn.  I think my only choice I have is to >> define the dsn in another 
MANAGEMENT Class and have DFHSM attributes for a backup  done.  Could 
there be another 
>> solution to my problem?
 
Maybe I'm missing something here & maybe this is too simplistic, but why 
not create a managment class with the correct attributes and use the 
IDCAMS ALTER command alter the command for the existing dataset? 
**************************************************************************************