Dear Russell Witt, Thanks for your information. Regards,
On 12/3/07, Russell Witt <[EMAIL PROTECTED]> wrote: > > You cannot call for scratch volume by specific-volser. If you are > attempting > write new data to a new tape; it should be without a volser and just > select > the next scratch volume. If you are attempting to read or mod data onto an > existing tape; the tape has been scratched (why?) inside the robot. In > that > case, you would need to "un-scratch" the tape (change its status to > PRIVATE) > using the ISMF panels and then re-submit the job. > > Russell Witt > L2 Support Manager > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] > Behalf Of RHK HK > Sent: Monday, December 03, 2007 6:37 AM > To: [email protected] > Subject: ATL 3590 problem > > > We are facing following problem with some Scratch tapes > Please help up. > Regards > [EMAIL PROTECTED] > RETURN CODE 8 REASON CODE 51 > THE MODULE THAT DETECTED THE ERROR IS IGDIDMUS > SMS MODULE TRACE BACK - IDMUS IDMSU IDM00 SSIRT > SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00042 > > IGD330I ERROR OCCURRED DURING CBRXLCS PROCESSING- > VOLUME REQUESTED BY SPECIFIC VOLUME SERIAL IS A SCRATCH VOLUME > THE FAILING VOLSER IS VOL244 > IGD306I UNEXPECTED ERROR DURING CBRXLCS PROCESSING > RETURN CODE 8 REASON CODE 51 > THE MODULE THAT DETECTED THE ERROR IS IGDIDMUS > SMS MODULE TRACE BACK - IDMUS IDMSU IDM00 SSIRT > SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00042 > > > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html