Leon:
The error occurred on a write count key data command X'1D' with the multi-trk
bit on, hence the 9d to device AA1A on chpid 52. I'd have the ce check it out
for that chpid. If this is a first time, it's not a bad idea anyway as It may
also be an error in software.
Bill
> Date: Mon, 7 Jan 2008 13:01:10 -0600> From: [EMAIL PROTECTED]> Subject:
> IOS050I CHANNEL DETECTED ERROR ON AA1A,52,9D,**02,PCHID=0142> To:
> [email protected]> > We have just connected some DASD at our remote site
> and when we are writing> data we get an" IOS050I CHANNEL DETECTED ERROR ON>
> AA1A,52,9D,**02,PCHID=0142" message. > > Here is the LOGREC info:> > SSYS ID
> REASON PSW-MCH /PROG-EC > RCYRYXI T COMP/MOD CSECTID ERROR-ID> > TIME JOBNAME
> RECTYP CP CUA DEVT CMD CSW SENSE 04 06 08 > 10 12 14 16 18 20 22 VOLUME SEEK
> SD CT> > * DNO CRW CHP SCSW > ESW STOR ADDR> > > DATE 007 08> > 09 10 04 88
> N/A MDR 00 0102 3590 51> > 09 10 04 92 N/A MDR 00 0102 3590 51> > 11 20 25 80
> ICEGENE2 SLH 00 AA1A 3390 52 84C240174AB4817000020000> 00806680 00000000> >
> Any idea's on how I can eliminate the IOS051I messages?> > Thanks > >
> ----------------------------------------------------------------------> For
> IBM-MAIN subscribe / signoff / archive access instructions,> send email to
> [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO> Search the archives at
> http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html