Al Sherkow said: 

> I think RMF/SMF70-1 will only have 'activated' LPARs regardless
> of being IPL'd or type of LPAR (MVS, IFL, Coupling Facility). 

I'm afraid that's not right: Inactive partitions show up in the LPAR 
sections but as having zero engines and zero memory. (I see them in raw 
SMF and in the RMF CPU Activity report. Today I don't process the sections 
for inactive LPARs and I'm beginning to think I should - for completeness 
or awareness of what the customer is doing with the machine.

Cheers, Martin