I recently created ARM policy couple datasets and loaded a policy to restart
just our automation product, CA-OPS/MVS. I ran some tests, canceling
OPS/MVS, and it restarted.

However, now I see (in the display below) that many tasks have automatically
registered with ARM. I was not expecting this, as I had to turn on a
parameter in OPS/MVS to have it begin registering with ARM.

I formatted my couple datasets to have room for 20 elements, although I
would only be needing a few. I see that the display has 20 lines. So it
appears that I need to format a larger ARM policy couple datasets.

I know that I can code OPS/MVS ARM rules to control ARM restarts, but I
assumed that I would only need that for tasks which were to be restarted by
ARM.

Some questions:

-What item should I key in on in the D XCF,ARMS,STATE=AVAIL display, the D
XCF,ARMS,EL=element display, or the IXCMIAPU report (or something else I
missed) to know that the registered tasks will or will not restart.

-Do I need to specify parms in each IBM product to turn ARM registration
off, or is registration okay, as long as the policy does not define a
restart_method

-I defined an element for each MVS system. Was that really necessary?

Regards,

Bob Stark 

ProTech - When you're serious about Systems Management
Consulting, Software, and Training for z/OS, UNIX and Internet
www.protechtraining.com   800-373-9188 x150   412-445-8072

A portion of the ARM policy:

RESTART_GROUP(DEFAULT)
FREE_CSA(250,700)
RESTART_PACING(1000)

ELEMENT(*)
RESTART_ATTEMPTS(1,150)
RESTART_TIMEOUT(150)
READY_TIMEOUT(150)

ELEMENT(OPSSSYSB)
RESTART_ATTEMPTS(2,500)
RESTART_TIMEOUT(30)
READY_TIMEOUT(500)
TERMTYPE(ALLTERM)
RESTART_METHOD(BOTH,STC,'START OPSS,SUB=MSTR')

ELEMENT(OPSSSYSC)
RESTART_ATTEMPTS(2,500)
RESTART_TIMEOUT(30)
READY_TIMEOUT(500)
TERMTYPE(ALLTERM)
RESTART_METHOD(BOTH,STC,'START OPSS,SUB=MSTR')

Output from MVS display:
D XCF,ARMS,STATE=AVAIL
IXC392I  01.07.47  DISPLAY XCF 094
ARM RESTARTS ARE ENABLED
-------------- ELEMENT STATE SUMMARY --------------   -TOTAL-
STARTING  AVAILABLE  FAILED  RESTARTING  RECOVERING
       0         20       0           0           0       20
RESTART GROUP:DEFAULT          PACING  : 1000    FREECSA:  25
 ELEMENT NAME     STATE        CURR SYS INIT SYS JOBNAME  ASI
 DB2$DTB1         AVAILABLE    SYSD     SYSD     DTB1MSTR 007
 EUVFKDC_SYSD     AVAILABLE    SYSD     SYSD     SKRBKDC  007
 EZASDTCPIPD      AVAILABLE    SYSD     SYSD     TCPIPD   005
 [EMAIL PROTECTED]       AVAILABLE    SYSD     SYSD     SDSF     008
 MSDTA1DTA@       AVAILABLE    SYSD     SYSD     [EMAIL PROTECTED] 007
 MSDTA1DTAD       AVAILABLE    SYSD     SYSD     DTADMSTR 008
 [EMAIL PROTECTED]    AVAILABLE    SYSD     SYSD     [EMAIL PROTECTED] 009
 MSXTA1XTAD001    AVAILABLE    SYSD     SYSD     DTADIRLM 009
 [EMAIL PROTECTED]         AVAILABLE    SYSD     SYSD     ACFNETD  005
 OPSSSYSD         AVAILABLE    SYSD     SYSD     OPSS     005
 SYS_RRS_SYSD     AVAILABLE    SYSD     SYSD     RRS      00C
 SYSCICS_CICSTC   AVAILABLE    SYSD     SYSD     CICSTC   024
 SYSMQCHCSQ1      AVAILABLE    SYSD     SYSD     CSQ1CHIN 028
 SYSMQCHQMD2      AVAILABLE    SYSD     SYSD     QMD2CHIN 00D
 SYSMQMGRCSQ1     AVAILABLE    SYSD     SYSD     CSQ1MSTR 00D
 SYSMQMGRQMD2     AVAILABLE    SYSD     SYSD     QMD2MSTR 00C
 SYSMQMGRQMD3     AVAILABLE    SYSD     SYSD     QMD3MSTR 00C
 VPSTCP           AVAILABLE    SYSD     SYSD     VPSTCP   006
 VSV              AVAILABLE    SYSD     SYSD     VSV      007
 XTB1001          AVAILABLE    SYSD     SYSD     DTB1IRLM 009

----------------------------------------------------------------------