Someone in-house wrote me (on an address that works):
> * Today they pick up the PTFs from the SMPPTS within engineering
> environments ... . This is apparently
> not guaranteed to work, because the PTFs are compressed on
> SMPPTS but the compression can be SMP/E level dependent. If
> [recipients] are running a different level of SMP/E to
> ..., the PTFs we send are not usable on
> their systems.
The SMP/E RM at:
http://publibz.boulder.ibm.com/cgi-bin/bookmgr_OS390/BOOKS/GIMRFR35/11.1
mentions no level sensitivity other than "where the SMP/E installed
on the other system cannot handle compacted inline element data".
Is it more likely that there's a level sensitivity, that the other
system is entirely compaction-naive (how far down must that be?), o
that we suffered data corruption in transmission?
Thanks,
gil
----------------------------------------------------------------------